| Welcome to McFarland-Tritan, LLC |
Fluid Sampling Systems
Crude oil prices necessitate accurate measurement of the BS&W content in oil. Manual sampling methods can result in samples with inaccurate and inconsistent values. Automatic Fluid Sampling Systems are designed to collect continuous, representative samples of oil and BS&W content in oil. Dependable sampling permits accurate determination of the BS&W percentage.
Economy Impulse-Actuated Electric Sampler for Flow Controlled Sampling When Connected to Fluid Meter or Time-Controlled Sampling when Connected to Timer:
This fluid sampling system is engineered for proportionate to flow sampling controlled by a fluid meter or other electrical impulse source and are cost-efficient for crude oil sampling on LACT units. The fluid sampling systems provide flexible installation - Example: sample probe installed in pipeline; line can be powered from meter or timed to solenoid. The Economy Impulse-Actuated Electric Sampler features 0 to 2.5 cubic centimeter-capacity adjustable sample volume regulator; solenoid-operated, explosion-proof three-way sampling valve and fluid inlet pressure regulator. This fluid sampling system is assembled on convenient mounting brackets. Sample volume regulator for larger size samples, from 0 to 10 cubic centimeters, is available. Supplied without pressure regulator and gauge for sampling when line pressure is below 50 pounds per square inch and relatively constant. Three-way solenoid sampling valve can be supplied "normally closed" for sample entry during the "power-on" time of the cycle. Solenoid valves are available for most power characteristics. A complete line of accessories includes McFarland-Tritan, LLC sample probes, sample containers and sample houses. Units can be modified for timer-controlled operations.
Impulse-Actuated Sampler with Motor-Driven, Slip-Stream Circulating Pump For Flow-Controlled or Time-Controlled Sampling:
This fluid sampling system features 1/2 horsepower, 3.5 gallon-per-minute, motor-driven pump for slip-stream circulating along with the standard Economy Sampler components. This Impulse-Actuated Sampler with Motor-Driven, Slip-Stream Circulating Pump For Flow-Controlled or Time-Controlled Sampling circulates fluid through the probe and by the solenoid-sampling valve at adequate velocity to keep water and solids in suspension. This fluid sampler system permits the installation of the sampler remote from the pipeline. Motors are available for most requirements. Installation is similar to the Economy Sampler, but with an added return circulation line and it provides constant-volume sampling when used with a timer. Sampling rates are fixed for any single setting of the timer, but other rates can be obtained by manual resetting of the timer. Can be customized for use with the Economic Sampler.
Impeller-Type Sampler For Flow Controlled Sampling (Proportional to Flow):
The Impeller-Type Sampler is installed as an integral part of the pipeline. No outside power or control is required. This Impeller-Type Sampler for flow-controlled sampling features an impeller-driven sampling probe and sample circulation return probe assembled to a blind flange and mounted on a tee-flanged outlet positioned inside pipeline. This system incorporates a rotary sampling valve, McFarland-Tritan, LLC sample volume regulator, inlet probe, return probe piping with shut-off valves and fluid pressure regulator. Rotary sampling valve and fluid-powered impeller control sampling frequency. Adjustable sample volume regulator, from 0 to 2.5 cubic centimeters controls sample size. Rotary sampling valve alternately connects the volume regulator to the probe for filling or to the sample container for emptying. Rotary sample valve, sample volume regulator and probe arrangement are designed to permit passage of sand and BS&W through the sampler without clogging or damage. No check valves are required- eliminating the potential for cutting or plugging. This fluid sampling system will mount on blind flange without tee or on existing pipelines by addition of a saddle, flanged outlet and hot tap. A 24-inch sampler is provided for lines above 24 inches-customer should advise dimension from center of pipeline to face of the sampler-mounting flange. The Impeller-Type Sampler can be supplied mounted on flanged side outlet of a plain end tee, beveled for welding into the pipeline. Flange size and pressure rating are matched to line requirements. Sample volume regulator capacity: 0 to 10 cubic centimeters. Special volume regulators available for large sample sizes. Accessories include sample container, sheet-metal house, companion flanges, and studs and gasket. Fluid flow provides the power and controls the sampling rate. Changes in the sampling rate are directly proportional to changes in the flow rate in the pipeline. Installed in horizontal or vertical lines in accordance with API sampling standards.
Custom Manufactured Systems: For Your Specific Requirements
| Fluid
Sampling Systems |
|
Crude oil prices
necessitate accurate measurement of the BS&W content in oil.
Manual sampling methods can result in samples with inaccurate and
inconsistent values.
Automatic
Fluid Sampling Systems
- Designed
to collect continuous, representative samples of oil and BS&W
- Dependable
sampling permits accurate determination of the BS&W percentage
|
 |
| Economy
Impulse-Actuated Electric Sampler For Flow Controlled Sampling When
Connected to Fluid Meter or Time-Controlled Sampling When Connected
to Timer |
- Engineered
for proportionate to flow sampling controlled by a fluid meter
or other electrical impulse source
- Cost-efficient
for crude oil sampling on LACT units
- Flexible
installation: sample probe installed in pipeline; line can be
powered from meter or timed to solenoid
- Features
0 to 2.5 cubic centimeter-capacity adjustable sample volume regulator;
solenoid-operated, explosion-proof three-way sampling valve and
fluid inlet pressure regulator
- Assembled
on convenient mounting bracket
- Sample volume
regulator for larger size samples, from 0 to 10 cubic centimeters,
is available
- Supplied
without pressure regulator and gauge for sampling when line pressure
is below 50 pounds per square inch and relatively constant
- Three-way
solenoid sampling valve can be supplied "normally closed" for
sample entry during the "power-on" time of the cycle
- Solenoid
valves are available for most power characteristics
- A complete
line of accessories includes McFarland-Tritan, LLC sample probes, sample containers
and sample houses
- Units can
be modified for timer-controlled operations
|
|
Economy
HP for uses up to 1,000 psi. No pressure regulator
Net Weight:
10lbs.
Shipping Cube: 8ft.
|
|
| Economac
Impulse-Actuated Sampler With Motor-Driven, Slip-Stream Circulating
Pump For Flow-Controlled or Time-Controlled Sampling |
- Features
1/2 horsepower, 3.5 gallon-per-minute, motor-driven pump for slip-stream
circulating along with the standard Economy Sampler components
- Circulates
fluid through the probe and by the solenoid sampling valve at
adequate velocity to keep water and solids in suspension
- Permits the
installation of the sampler remote from the pipeline
- Motors available
for most requirements
- Installation
similar to the Economy Sampler, but with an added return circulation
line
- Provides
constant-volume sampling when used with a timer
- Sampling
rates are fixed for any single setting of the timer, but other
rates can be obtained by manual resetting of the timer
- Can be customized
for use with the Economac Sampler
|
 |
| Impeller-Type
Sampler For Flow Controlled Sampling (Proportional to
Flow) |
- Installed
as an integral part of the pipeline
- No outside
power or control is required
- Features
an impeller-driven sampling probe and sample circulation return
probe assembled to a blind flange and mounted on a tee-flanged
outlet positioned inside pipeline
- Incorporates
a rotary sampling valve, McFarland-Tritan, LLC sample volume regulator, inlet
probe, return probe piping with shut-off valves and fluid pressure
regulator
- Rotary sampling
valve and fluid-powered impeller control sampling frequency
- Adjustable
sample volume regulator, from 0 to 2.5 cubic centimeters controls
sample size
- Rotary sampling
valve alternately connects the volume regulator to the probe for
filling or to the sample container for emptying
- Rotary sample
valve, sample volume regulator and probe arrangement designed
to permit passage of sand and BS&W through the sampler without
clogging or damage
- No check
valves are required- eliminating the potential for cutting or
plugging
- Will mount
on blind flange without tee or on existing pipelines by addition
of a saddle, flanged outlet and hot tap
- A 24-inch
sampler is provided for lines above 24 inches-customer should
advise dimension from center of pipeline to face of the sampler
mounting flange
- Can be supplied
mounted on flanged side outlet of a plain end tee, beveled for
welding into the pipeline
- Flange size
and pressure rating are matched to line requirements
- Sample volume
regulator capacity: 0 to 10 cubic centimeters
- Special volume
regulators available for large sample sizes
- Accessories
include sample container, sheet-metal house, companion flanges,
and studs and gaskets
- Fluid flow
provides the power and controls the sampling rate
- Changes in
the sampling rate are directly proportional to changes in the
flow rate in the pipeline
- Installed
in horizontal or vertical lines in accordance with API sampling
standards
| Nominal
Pipe Size (in.) |
Approximate
Barrels Transmitted/Sample |
150
lb. Mounting Flanges |
300
lb. Mounting Flanges |
| Length
Flange to Flange (in.) |
Width
(in.) |
Height
C/L to Top (in.) |
Length
Flange to Flange (in.) |
Width
(in.) |
Height
C/L to Top (in.) |
| 2
1/2* |
1.0 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 3* |
.8 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 4* |
.6 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 6 |
.5 |
11
1/4 |
11 |
18
7/8 |
11
1/4 |
12
1/2 |
19
3/8 |
| 8 |
1.5 |
14 |
13
1/2 |
20 |
14 |
15 |
20
1/2 |
| 10 |
3.0 |
17 |
16 |
21
1/8 |
17 |
17
1/2 |
21
3/4 |
| 12 |
7.0 |
20 |
19 |
24
1/8 |
20 |
20
1/2 |
24
7/8 |
| 14 |
10.0 |
22 |
21 |
25
3/8 |
22 |
23 |
26
1/8 |
| 16 |
14.0 |
24 |
23
1/2 |
26
5/8 |
24 |
25
1/2 |
27
3/8 |
| 18 |
17.0 |
27 |
25 |
27
3/8 |
27 |
28 |
29
1/8 |
| 20 |
24.0 |
30 |
27
1/2 |
30
1/8 |
30 |
30
1/2 |
30
7/8 |
| 24 |
33.0 |
34 |
32 |
32
1/2 |
34 |
36 |
33
3/8 |
|
|
*Standard
6” sampler with end reducers used under 6”
Note: Maximum unit sample volume: 10 cc.
|
|
 |
|
|
| 921 Seaco Court . Deer Park, TX 77536 . USA . Phone: 713-864-3366 . Fax: 713-864-3252 |
| Site Map | Site Credits: Ecreativeworks |